Modem Configuration Data for Hylafax supported by Xtreme Webdesign Fa. T. Mueller www.xtremeweb.de
Config ID = 225f |
Manufacturer | Multi-Tech Systems |
---|---|
Model | 5600ZDX |
Firmware | V2.300-V90_2M_DLS |
Operation Mode | Class 2.0 RTSCTS |
Config | # # Configuration for a Multitech 5600ZDX Class 2 modem. # # This configuration file sets up the modem to run at 38.4 for # sending and for receiving. RTS/CTS is used for flow control # which also works for data connections. # # CONFIG: CLASS2: MULTITECH 5600ZDX # # BEGIN-SERVER # END-SERVER CountryCode: 1 AreaCode: 425 FAXNumber: 425-000-0000 LongDistancePrefix: 1 InternationalPrefix: 011 DialStringRules: etc/dialrules ServerTracing: 1 #SessionTracing: 11 SessionTracing: 0xFFF RecvFileMode: 0644 LogFileMode: 0644 DeviceMode: 0600 RingsBeforeAnswer: 1 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "425-000-0000" TagLineFont: etc/lutRS18.pcf TagLineFormat: "From %%l|%c - Job %i|Page %%p of %%t" PercentGoodLines: 90 MaxConsecutiveBadLines: 10 MaxRecvPages: 9999 # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class2 # use class 2 interface ModemRate: 38400 # lock rate for DCE-DTE # communication ModemFlowControl: rtscts # default # ModemHardFlowCmd: AT&E4 # hardware flow control ModemSoftFlowCmd: AT&E5 # software flow control ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets # modem ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier # (or not) ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in # class 2 # # NB: some models get confused by the @ # ModemDialCmd: ATDT%s # T for tone dialing, @ for # silence # ModemSendFillOrder: LSB2MSB # as expected ModemRecvFillOrder: MSB2LSB # opposite of what makes sense Class2RecvDataTrigger: "\022" # character sent to modem to # start recv |
Main Usage | sending + receiving |
Outgoing faxes per day | 6 |
Incoming faxes per day | 100 |
Comments | Modem is behind a PBX with Automatic Route Selection capabilities, therefore dialing pauses (,) are not necessary for outbound faxing. Modem / Firmware Information: Multitech MT5600ZDX ati0 ati4 MT5600ZDX a007840284C6002F OK bC60000000 ati1 r1005111151012000 241 r3000111170000000 OK OK ati2 ati5 OK 022 ati3 OK V2.300-V90_2M_DLS ati6 OK RCV56DPF-PLL L8571A Rev 36.00/36.00 AT+FCLASS=? OK 0,1,2,1.0 ati7 OK OK AT+FDCC=? (0,1),(0-5),(0-2),(0-2),0,0,0,(0-7) OK at+FAA=? 0,1 OK at+FAE=? 0,1 OK at+FBOR=? 0-3 OK AT+FREL=? 0 OK AT+FCQ=? 0 OK AT+FTBC=? 0 OK AT+FCR=? 0,1 OK AT+FPHCTO=? 0-255 OK AT+FBUG=? 0 OK AT+FLID=? (20)(32,33,35-96,123-126) OK AT+FDIS=? (0,1),(0-5),(0-2),(0-2),0,0,0,(0-7) OK AT+FCIG=? (20)(32,33,35-96,123-126) OK AT+FPTS=? 1-5 OK AT+FSPL=? 0,1 OK |
Name | MT5600ZDX Inbound & Outbound |
kenneth_abrahamsen@mcgraw-hill.com | |
Entered 198.45.18.20 2001/10/30 21:09 |