Modem Configuration Data for Hylafax supported by Xtreme Webdesign Fa. T. Mueller www.xtremeweb.de
Config ID = 225f |
| Manufacturer | Multi-Tech Systems |
|---|---|
| Model | 5600ZDX |
| Firmware | V2.300-V90_2M_DLS |
| Operation Mode | Class 2.0 RTSCTS |
| Config | #
# Configuration for a Multitech 5600ZDX Class 2 modem.
#
# This configuration file sets up the modem to run at 38.4 for
# sending and for receiving. RTS/CTS is used for flow control
# which also works for data connections.
#
# CONFIG: CLASS2: MULTITECH 5600ZDX
#
# BEGIN-SERVER
# END-SERVER
CountryCode: 1
AreaCode: 425
FAXNumber: 425-000-0000
LongDistancePrefix: 1
InternationalPrefix: 011
DialStringRules: etc/dialrules
ServerTracing: 1
#SessionTracing: 11
SessionTracing: 0xFFF
RecvFileMode: 0644
LogFileMode: 0644
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "425-000-0000"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c - Job %i|Page %%p of %%t"
PercentGoodLines: 90
MaxConsecutiveBadLines: 10
MaxRecvPages: 9999
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 38400 # lock rate for DCE-DTE
# communication
ModemFlowControl: rtscts # default
#
ModemHardFlowCmd: AT&E4 # hardware flow control
ModemSoftFlowCmd: AT&E5 # software flow control
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets
# modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
# (or not)
ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in
# class 2
#
# NB: some models get confused by the @
#
ModemDialCmd: ATDT%s # T for tone dialing, @ for
# silence
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
Class2RecvDataTrigger: "\022" # character sent to modem to
# start recv
|
| Main Usage | sending + receiving |
| Outgoing faxes per day | 6 |
| Incoming faxes per day | 100 |
| Comments | Modem is behind a PBX with Automatic Route Selection capabilities, therefore dialing pauses (,) are not necessary for outbound faxing. Modem / Firmware Information: Multitech MT5600ZDX ati0 ati4 MT5600ZDX a007840284C6002F OK bC60000000 ati1 r1005111151012000 241 r3000111170000000 OK OK ati2 ati5 OK 022 ati3 OK V2.300-V90_2M_DLS ati6 OK RCV56DPF-PLL L8571A Rev 36.00/36.00 AT+FCLASS=? OK 0,1,2,1.0 ati7 OK OK AT+FDCC=? (0,1),(0-5),(0-2),(0-2),0,0,0,(0-7) OK at+FAA=? 0,1 OK at+FAE=? 0,1 OK at+FBOR=? 0-3 OK AT+FREL=? 0 OK AT+FCQ=? 0 OK AT+FTBC=? 0 OK AT+FCR=? 0,1 OK AT+FPHCTO=? 0-255 OK AT+FBUG=? 0 OK AT+FLID=? (20)(32,33,35-96,123-126) OK AT+FDIS=? (0,1),(0-5),(0-2),(0-2),0,0,0,(0-7) OK AT+FCIG=? (20)(32,33,35-96,123-126) OK AT+FPTS=? 1-5 OK AT+FSPL=? 0,1 OK |
| Name | MT5600ZDX Inbound & Outbound |
| kenneth_abrahamsen@mcgraw-hill.com | |
| Entered 198.45.18.20 2001/10/30 21:09 | |
|
|