Modem Configuration Data for Hylafax supported by Xtreme Webdesign Fa. T. Mueller www.xtremeweb.de
Config ID = 225f

Manufacturer Multi-Tech Systems
Model 5600ZDX
Firmware V2.300-V90_2M_DLS
Operation Mode Class 2.0 RTSCTS
Config
#
# Configuration for a Multitech 5600ZDX Class 2 modem.
#
# This configuration file sets up the modem to run at 38.4 for
# sending and for receiving.  RTS/CTS is used for flow control
# which also works for data connections.
#
# CONFIG: CLASS2: MULTITECH 5600ZDX
#
# BEGIN-SERVER
# END-SERVER
CountryCode:            1
AreaCode:               425
FAXNumber:              425-000-0000
LongDistancePrefix:     1
InternationalPrefix:    011
DialStringRules:        etc/dialrules
ServerTracing:          1
#SessionTracing:         11
SessionTracing:         0xFFF
RecvFileMode:           0644
LogFileMode:            0644
DeviceMode:             0600
RingsBeforeAnswer:      1
SpeakerVolume:          off
GettyArgs:              "-h %l dx_%s"
LocalIdentifier:        "425-000-0000"
TagLineFont:            etc/lutRS18.pcf
TagLineFormat:          "From %%l|%c - Job %i|Page %%p of %%t"
PercentGoodLines:       90
MaxConsecutiveBadLines: 10
MaxRecvPages:           9999

#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:              Class2          # use class 2 interface
ModemRate:              38400           # lock rate for DCE-DTE
                                        # communication
ModemFlowControl:       rtscts          # default
#
ModemHardFlowCmd:       AT&E4           # hardware flow control
ModemSoftFlowCmd:       AT&E5           # software flow control
ModemSetupDTRCmd:       AT&D3           # setup so DTR drop resets
                                        # modem
ModemSetupDCDCmd:       AT&C1           # setup so DCD reflects carrier
                                        # (or not)
ModemSetupAACmd:        AT+FAA=1        # enable adaptive-answer in
                                        # class 2
#
# NB: some models get confused by the @
#
ModemDialCmd:           ATDT%s          # T for tone dialing, @ for
                                        # silence
#
ModemSendFillOrder:     LSB2MSB         # as expected
ModemRecvFillOrder:     MSB2LSB         # opposite of what makes sense
Class2RecvDataTrigger:  "\022"          # character sent to modem to
                                        # start recv
Main Usage sending + receiving
Outgoing faxes per day 6
Incoming faxes per day 100
Comments
Modem is behind a PBX with Automatic Route Selection capabilities, therefore dialing pauses (,) are not necessary for outbound faxing.

Modem / Firmware Information:
Multitech MT5600ZDX
ati0			ati4
MT5600ZDX		a007840284C6002F
OK			bC60000000
ati1			r1005111151012000
241			r3000111170000000
OK			OK
ati2			ati5
OK			022
ati3			OK
V2.300-V90_2M_DLS	ati6
OK			RCV56DPF-PLL L8571A Rev 36.00/36.00
AT+FCLASS=?		OK
0,1,2,1.0		ati7
OK			OK
AT+FDCC=?
(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7)
OK
at+FAA=?
0,1
OK
at+FAE=?
0,1
OK
at+FBOR=?
0-3
OK
AT+FREL=?
0
OK
AT+FCQ=?
0
OK
AT+FTBC=?
0
OK
AT+FCR=?
0,1
OK
AT+FPHCTO=?
0-255
OK
AT+FBUG=?
0
OK
AT+FLID=?
(20)(32,33,35-96,123-126)
OK
AT+FDIS=?
(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7)
OK
AT+FCIG=?
(20)(32,33,35-96,123-126)
OK
AT+FPTS=?
1-5
OK
AT+FSPL=?
0,1
OK
Name MT5600ZDX Inbound & Outbound