Modem Configuration Data for Hylafax supported by Xtreme Webdesign Fa. T. Mueller www.xtremeweb.de
Config ID = 5982

Manufacturer Mainpine
Model RockForceQUATRO+
Firmware 03.04.00 (0007)
Operation Mode Class 1 RTSCTS
Config
# $Id: mainpine-rf-1,v 1.2 2000/09/04 18:53:45 lhoward Exp $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

# Configuration file for Mainpine RockforceQUATRO+ Multiport V.34 Fax PCI card
# use default configuration

# CONFIG:CLASS1:Mainpine Venus V.92 I03.04.00 *:.*:.*: Manufacturer=Mainpine Model=RockforceQUATRO+
#
# BEGIN-SERVER
# END-SERVER
#

#ModemAnswerCmd:			ATA	# string, command for answering phone
#ModemAnswerDataBeginCmd:	""	# string, command for start of answered data call
#ModemAnswerDataCmd:		ATA	# string, command for answering data call
#ModemAnswerFaxBeginCmd:		""	# string, command for start of answered fax call
#ModemAnswerFaxCmd:		ATA	# string, command for answering fax call
#ModemAnswerResponseTimeout:	180000	# integer, answer command timeout (ms)
#ModemAnswerVoiceBeginCmd:	""	# string, command for start of answered voice call
#ModemAnswerVoiceCmd:		ATA	# string, command for answering voice call
#ModemATCmdDelay:		0	# integer, delay before sending modem an AT cmd (ms)
#ModemBaudRateDelay:		0	# integer, delay (ms) after setting baud rate
#ModemClassQueryCmd:		AT+FCLASS=?	# string, command for querying modem services
#ModemCommaPauseTimeCmd:		ATS8=2	# string, command for setting time to pause for comma in dialing string
#ModemDialCmd:			ATDT%s	# string, command for dialing (%s for number to dial)
#ModemDialResponseTimeout:	180000	# integer, dialing command timeout (ms)
#ModemEchoOffCmd:		ATE0	# string, command for disabling command echo
#ModemFlowControl:		None	# string, DTE-DCE flow control scheme
#ModemFrameFillOrder:		LSB2MSB	# string, bit order for HDLC frames
#ModemHardFlowCmd:		""	# string, command for setting hardware flow control between DTE and DCE
#ModemMinSpeed:			2400	# string, minimum acceptable transmit speed
#ModemMfrQueryCmd:		""	# string, command for querying modem manufacturer
#ModemModelQueryCmd:		""	# string, command for querying modem model
#ModemNoAutoAnswerCmd:		ATS0=0	# string, command for disabling auto-answer
#ModemNoFlowCmd:			""	# string, command for disabling hardware flow control between DTE and DCE
#ModemOnHookCmd:			ATH0	# string, command for placing phone ``on hook''
#ModemPageDoneTimeout:		180000	# integer, page send/receive timeout (ms)
#ModemPageStartTimeout:		180000	# integer, page send/receive timeout (ms)
#ModemRate:			19200	# integer, baud rate to use for DCE-DTE communication
#ModemRecvFillOrder:		LSB2MSB	# string, bit order for received facsimile data
#ModemResetCmds:			""	# string, additional commands when resetting modem
#ModemResetDelay:		2600	# integer, delay (ms) after sending modem reset commands
#ModemResultCodesCmd:		ATQ0	# string, command for enabling result codes
#ModemRevQueryCmd:		""	# string, command for querying modem firmware revision
#ModemSendBeginCmd:		""	# string, command to send on establishing carrier
#ModemSendFillOrder:		LSB2MSB	# string, bit order for sending facsimile data
#ModemSetVolumeCmd:		"ATM0 ATL0M1 ATL8C1 ATL2M1 ATL3M1"	# string, commands for setting modem speaker volume level
#ModemSetupAACmd:		""	# string, command for setting up adaptive answer
#ModemSetupDCDCmd:		""	# string, command for setting up DCD handling
#ModemSetupDTRCmd:		""	# string, command for setting up DTR handling
#ModemSoftFlowCmd:		""	# string, command for setting software flow control between DTE and DCE
#ModemSoftResetCmd:		ATZ	# string, command for doing a soft reset
#ModemType:			Class1	# string, modem type
#ModemVerboseResultsCmd:		ATV1	# string, command for enabling verbose result codes
#ModemWaitForConnect:		No	# boolean, force server to wait for ``CONNECT'' response on answer
#ModemWaitTimeCmd:		ATS7=60	# string, command for setting time to wait for carrier when dialing

#Class1Cmd:			AT+FCLASS=1	# string, command to enter class 1
#Class1HFLOCmd:			""	# string, command to set hardware flow control
#Class1FrameOverhead:		4	# integer, extra bytes in a received HDLC frame
#Class1NFLOCmd:			""	# string, command to set no flow control
#Class1RecvAbortOK:		100	# integer, max wait (ms) for ``OK'' after recv abort
#Class1RecvIdentTimer:		35000	# integer, max wait (ms) for initial ident frame
#Class1SFLOCmd:			""	# string, command to set software flow control
#Class1TCFMaxNonZero:		10	# integer, max% of non-zero data in good TCF
#Class1TCFMinRun:		1000	# integer, minimum zero run in good TCF
#Class1TCFRecvTimeout:		4500	# integer, max wait (ms) for TCF
#Class1TCFResponseDelay:		75	# integer, delay between TCF and ack/nak
#Class1SendPPMDelay:		75	# integer, delay before sending post-page message
#Class1SendTCFDelay:		75	# integer, delay between sending DCS and TCF
#Class1TrainingRecovery:		1500	# integer, delay after failed training

Main Usage sending + receiving
Outgoing faxes per day 1
Incoming faxes per day 1
Comments
faxaddmodem needs to be run 4 times, once for each modem on the multiport card
Name Andrew Rinaldi
E-Mail andrew.rinaldi@mainpine.com
Entered 62.24.230.127 2003/03/10 19:11


modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)modify the informationdelete entire recordHOMELOGIN (you are guest)   Web Oriented Database Home